STEP 4 (Figure 2.15) Gently pull the coil cable from inside the yoke/
lower shaft.
STEP 5 (Figure 2.16). Carefully feed the coil cable of the new coil
back into yoke and lower shaft. Continue to feed the cable
into the shaft unitl the connector is visible at the top of the
shaft.
Note: It may be easier to pull the cable through the lower
shaft using a length of string or cord. Once this is completed
you should be able to see approximately 4 inches (100mm)
of cable between the coil yoke and the search coil. This is
the slack necessary to allow adjustment to the angle of the
search coil.
STEP 6 Re-attach the yoke and the search coil. Be careful not to
damage the thread of the nut by over-tightening. See Figure
2.2 and 2.3.
STEP 7 Reconnect cable to control box (as directed in Connecting
the shaft assembly, page 16).
REPLACING AND FITTING THE SEARCH COIL
Figure 2.16 Removing the coil cable
Pull Coil Cable
up inside of
yoke/shaft
P0613-A