front controls
– continued
page 30
l 4 controls and operation l
GP 3500
page 30
Operating the GP 3500 in Fixed mode
In medium to quiet ground you will achieve better depth by operating your GP 3500 in the
Fixed position and using the Quick-Trak push button to re-balance when the ground changes
and/or threshold becomes erratic. If the ground is highly mineralized or variable, then
searching in Tracking may be the preferred position.
HINTS
Where possible always search in Fixed position for best depth and only use Tracking mode
in areas with excessive ground noise or rapidly changing ground.
When searching in Fixed position remember to re-balance periodically by pressing the
Quick-Trak push button in the handle. This returns you to Fixed once the re-balance is
completed and you release the button.
Always Pinpoint a potential target in Fixed.
If mineralization is excessive you may need to lift the coil off the ground by a cm or two,
rather than keeping it right on the ground. This will help to reduce the effects of high
ground mineralization and let you hear more targets much easier.
front controls
– continued
l 4 controls and operation l
page 31
GP 3500 GP 3500
www.minelab.com
page 31
Operating the GP 3500 in Tracking mode
If the ground is highly mineralized or variable, search in Tracking mode.
To search in Tracking mode, switch the Fixed / Tracking switch on the control box into
Tracking position.
In this position the detector is continuously testing and re-balancing to compensate for
changes in the ground mineralization. There are three tracking speeds that you can search
in – Fast; Medium & Slow. – see next chapter for details.
When searching in Tracking mode, the Quick-Trak push button takes you into Fixed mode
while the button is depressed.
While in Tracking mode, the detector usually stops ground balancing when a target signal is
detected. However, a weak target response may not be recognised as a target if the coil is
repeatedly passed over it, and especially if operating in medium or fast tracking.
For this reason the push button should be used to change to Fixed when pinpointing a target.
When searching in Tracking, after locating a target or what you believe is a target, sweep the
coil around the target area, without passing across it, then hold in the Quick-Trak push button
and pinpoint the target location.
When releasing the button, the detector engages a short, fast tracking mode (indicated by a
beep) then returns to the Tracking mode.
TIP: When in tracking, you can use the push button as a ground balance reset.
Simply raise and lower the coil a few centimeters, periodically to check the
ground balance, and if it not completely balanced just push and release the
button while continuing the ground balance procedure.