F3 INSTRUCTOR NOTES
Minelab Countermine Division Safety Through Excellence
20
Noise Cancel will commence with two single beeps followed by 45
seconds of sharp double beeps finishing with four single beeps.
(Embedded wav file in slide)
During the 45 seconds, the detector scans the environment
searching for the source of any electrical interference. Once
detected, the F3 will automatically select a different operating
frequency to eliminate or reduce the interference.
Seventeen
cont
o Audio Reset. Whenever the Threshold Tone sounds louder than
normal perform Audio Reset.
NOTE
The detector cannot be used for clearing operations during the Audio Reset
procedure.
Audio Reset should be carried out whenever the threshold volume
seems louder than normal.
Hold the coil at least 600mm (24ins) off the ground and away from
any metallic objects.
Press and immediately release the Ground Balance button
(Green Button located on top of the Handle -if the button is held
too long, the detector will begin to Ground Balance).
Within two seconds the threshold tone will return to its correct
level.
Once Noise Cancel or Audio Reset is complete, continue with
Steps 2 and 3. Once completed, the F3 can now be used for
demining operations in compliance with local Standard Operating