On switch on, the
“Coil Fault” tone
occurs - “low pitched
double tone every
five seconds”
check the coil plug is firmly secured to the electronics pack
inspect coil cable for damage – if no damage replace
electronics pack
if damaged replace with new coil
On switch on, the
“Equipment Fault”
tone occurs – “low
pitched slow
oscillating tone (ee-
aww, ee-aww)
check endcap is secure
replace electronics pack
After working in hot
conditions, detector
makes a loud noise
conduct Audio Reset
replace coil
replace electronics pack
replace wiring loom
Ground Balance
does not work
replace speaker pod
replace wiring loom
replace coil
replace electronics pack
Noise Cancel does
not work
(no Noise Cancel
tones emitted)
Note: Noise Cancel may not completely remove the effects of
interference if the source is powerful or in close proximity
repeat Noise Cancel
replace wiring loom
replace electronics pack
Audio Reset does
not work
replace speaker pod
replace wiring loom
replace coil
LEDs do not
illuminate (F3L only)
ensure detector is F3L configuration - if not speaker pod is
incorrectly matched
pressing and hold the
button and quickly press and release
the green ground balance button.
replace speaker pod (F3L version)
Cannot hear the
Test Piece
ensure detector has been switched on for 30 secs before
conducting the test
conduct Audio Reset
fit and use an earset
if using an F3L ensure volume level is set to default
conduct Noise Cancel
ensure coil plug is securely fitted to electronics pack
replace electronics pack
replace coil
Start Up tones keep
repeating
insert new batteries
replace electronics pack
replace wiring loom
In the collapsed
position the detector
makes a loud noise
when coil is tilted
conduct Audio Reset
extend shafts
conduct Audio Reset
Earset does not
work
replace earset
replace wiring loom
Shafts will not
collapse
fully extend (leave for five minutes) very slowly collapse shafts
remove coil and remove any dirt located in the shaft and on the
cable – inspect cable for any damage – if none ensure the coil
has 52 turns and assemble back into the detector – fit coil pin if
not present
if cable damaged replace with new coil