F1A4 Field Service Manual – Level 1 and Level 2 Maintenance
Page 8
2.2 FUNCTIONAL TESTING
This section details functional testing of the F1A4. It should be used to
confirm serviceability of an F1A4 before it is returned to the field for use and
whenever doubt exists about the serviceability of an F1A4. The F1A4 must pass all
these tests to be considered serviceable. Remedial action is included for repair if
required. If remedial action is completed (ie the F1A4 is repaired using these
procedures), the full functional test should be repeated from Section 2.2.1.
A
Ground Balance (GB) Test Piece
is required to properly test the F1A4.
This is needed to simulate mineralised or “noisy” ground and ensure correct F1A4
Ground Balance operation. The GB Test Piece can be a local piece of mineralised
ground (hot rock or a fired tile) that produces a response from the F1A4.
Procedure:
Ensure the coil connector ‘clicks’ in to the socket. If the coil
plug does not ‘click’ in, replace the coil plug washer, if the coil
plug still does not ‘click’ in, send the coil to an accredited F1A4
Level 2 maintenance workshop.
Note: The Coil must not be near any metal objects, and the technician must not wear
any rings, bracelets, or watches during this procedure.
2.2.1 Initial Power On Test
Switch the F1A4 on to the Search position. The detector should take six
seconds to run through the start up routine, comprising four rising tones followed by
a continuous background threshold tone. F1A4 target response is indicated by a
clear change in the threshold tone. The amount of change is dependent on the size
of the target (larger target – louder response) and the distance from the coil to the
target (closer to coil – louder response). If the correct tones or threshold are not
heard the faulty control box (or battery carrier) should be replaced or the F1A4
should be sent to an accredited F1A4 Level 2 maintenance workshop.
2.2.2 Sensitivity Testing
Hold the Test Piece Mine Detector in one hand, with the end containing the
target away from the Coil. Move the
Test Piece Mine Detector
towards the centre
of the coil until it lightly touches the centre of the coil and then move it sideways off
the coil (the
Test Piece Mine Detector
should be moved slowly and smoothly during
this procedure). A soft but distinct change in the threshold tone should be heard.
P0263-B
If a response is not heard replace the faulty Control Box (or Coil, see Section
3.4) or the F1A4 should be sent to an accredited F1A4 Level 2 maintenance
workshop for repair.